Empty test
Use an empty clamshell from the affected lot and attempt normal closure. Note whether it fails to latch, initially latches and springs back, or shows another alignment problem.
Filled test
Repeat with the intended fruit and fill level, including a representative large-fruit pack. Photograph fruit or stems touching the closing plane and record the point of interference.
Alignment
Photograph the hinge and corresponding latch parts before applying additional pressure. Number each latch point and compare empty and filled samples taken from the same drawing version.
Revision
After an improvement, retest both empty and filled packs, including reopening and ordinary handling. Approve the change only against a named revision and retained samples.
Clamshell closure comparison
| Record | What to capture | Your notes |
|---|---|---|
| Empty test | Empty sample, latch result and failed location | |
| Filled test | Filled sample, fill weight, clearance and interference photo | |
| Alignment | Hinge/latch ID, alignment, drawing revision and photos | |
| Revision | Trial change, reopen/handling results and retained references |
Questions buyers ask
What should be checked before changing the latch?
Check empty closure, fill geometry and flange distortion to isolate the issue.
Does a one-off successful closure prove approval?
No. Agree representative samples and repeated handling conditions.