Map
Mark each corner, wall and floor location on a drawing or sample image. Use the same location IDs across samples so a low reading can be traced back to a specific part of the cavity.
Baseline
Record sheet gauge and lot, drawing revision, tool and process settings before the comparison. Keep sheet-gauge readings and formed-wall readings in separate columns.
Trial
Hold the other agreed variables steady while changing one forming condition. Repeat the measurement map on a clearly labeled set of parts and report the sample count and readings by location.
Decision
A repeated low reading in one part location prompts a geometry and process review. A shift across locations can justify checking incoming sheet evidence as well. Confirm a candidate change in a new trial.
Wall thickness measurement map
| Point ID | Region | Formed wall (mm) | Sample and observation |
|---|---|---|---|
| C1–C4 | Repeat one row for each corner radius | ||
| W1–W4 | Sidewalls with the measurement height recorded | ||
| B1 | Floor centre | ||
| Control | Record incoming gauge separately | ||
| Trial stage | Record lot, setup and changed variable |
Questions buyers ask
Should gauge be increased first?
First document the thickness pattern and process; the cause may not be overall gauge.
What evidence helps a supplier?
An annotated thickness map, drawing revision and linked sheet batch.